H-K9L Optical Glass Cutting Test: TTV & Ra Results

Finished 6 mm H-K9L optical glass sheet after endless diamond wire cutting

H-K9L Optical Glass Cutting Test: TTV & Ra Results

Ensoll conducted this cutting test on H-K9L (Schott-type) optical glass supplied by a European customer. The objective was to produce 6 mm sheets from a 70 x 70 x 70 mm block while controlling thickness variation, rugosidade superficial, and edge chipping. The test used an ESO-GM endless diamond wire saw with a 0.45 mm fully coated Loop de fio de diamante.

Principais Conclusões

  • H-K9L crown optical glass — comparable to Schott N-BK7 in many applications — was cut from a 70 x 70 x 70 mm block into 6 mm sheets on an ESO-GM diamond wire saw with a 0.45 mm fully coated wire loop.
  • Ten samples achieved TTV of 0.003-0.015 milímetro (8 de 10 at or below 0.010 milímetro), average thickness within +/-0.010 mm of nominal, mean Ra of 0.82 micrómetros, and maximum edge chipping under 10 micrómetros.
  • Key process conditions: 24 velocidade do fio m/s, a slow 5 avanço mm/min, 160 tensão N, cutting-oil lubrication, a 20-minute no-load wire pre-run, and wire-wear compensation adjusted from 0.47 para 0.48 milímetro.
  • The data give engineers a practical baseline for precision slicing of optical glass before grinding and polishing; parameters should still be re-validated for each glass composition, geometry and quality requirement.

This test is one data point in a wider picture — the full method is described under corte óptico de vidro.

Test Result at a Glance

  • Finished sheet size: 6 x 70 x 70 milímetro
  • TTV: 0.003-0.015 mm across 10 samples; 8 de 10 samples were at or below 0.010 milímetro
  • Average thickness range: 5.992-6.008 milímetro
  • Thickness tolerance: within +/-0.010 milímetro
  • Average surface roughness (Ra): 0.72-0.94 micrómetros; overall mean 0.82 micrómetros
  • Maximum edge chipping: below 10 micrometers for every sample
ESO-GM endless diamond wire saw used for the H-K9L optical glass cutting test
Figura 1. ESO-GM endless serra de fio de diamante used in the test.

1. Test Object and Cutting Objective

H-K9L is a crown optical glass comparable to Schott N-BK7 in many optical applications. The supplied block measured 70 x 70 x 70 mm and had an approximate Mohs hardness of 6. The customer required 6 mm sheets with tight dimensional consistency and a cut surface suitable for subsequent grinding and polishing.

An endless diamond wire process was selected because its narrow kerf, continuous unidirectional cutting action, and controlled contact load are well suited to valuable hard and brittle materials. The process also helps limit vibration, perda de material, and edge damage compared with conventional blade cutting.

2. Equipment, Fio, and Process Parameters

The test used the gantry-type ESO-GM diamond wire saw. Its rigid cast-iron structure, vertical top-down feed, automatic tension control, wire-break memory, and mist-removal system support stable precision cutting. A dedicated fixture was prepared for repeatable positioning of the 70 mm glass block.

ParâmetroValor
MáquinaESO-GM
Wire specification0.45 x 1880 milímetro, fully coated
Wire feed speed5 mm/min
Largura de corte70 milímetro
Tensão do fio160 Terminais de PCB retos de microinterruptor miniatura com êmbolo de pino
Velocidade linear24 EM
Wire bowing time60 s
Cooling and lubricationCutting oil

Cutting oil was used for combined cooling and lubrication. Before cutting, the new Loop de fio de diamante was run without load for 20 minutes to remove loosely attached abrasive particles and stabilize the wire. During the test, the wire-diameter compensation value was adjusted from 0.47 para 0.48 mm in response to observed wire wear.

ESO-GM parameter interface during H-K9L optical glass cutting
Figura 2. Cutting-process parameter interface.
H-K9L optical glass block being cut with an endless diamond wire
Figura 3. H-K9L optical glass during endless diamond wire cutting.

3. TTV Measurement Results

Total thickness variation (TTV) was measured on each 70 x 70 x 6 mm sheet using a nine-point grid and a dual-probe thickness measurement system on a vacuum adsorption stage. The instrument was thermally stabilized and calibrated with a standard thickness block before measurement. Each cleaned sample was centered on the stage, and vacuum adsorption was used to reduce the influence of substrate warpage.

AmostraNine-point thickness values (milímetro)TmaxTminTTV
S015.994, 5.991, 5.991
5.991, 5.992, 5.993
5.991, 5.992, 5.991
5.9945.9910.003
S026.004, 6.001, 6.004
5.999, 6.002, 6.003
6.001, 6.002, 6.000
6.0045.9990.005
S035.993, 5.998, 5.992
5.999, 5.996, 5.995
5.994, 5.997, 5.993
5.9995.9920.007
S046.001, 6.000, 6.005
6.004, 6.002, 6.003
6.001, 6.004, 6.002
6.0056.0000.005
S056.003, 6.000, 6.013
6.015, 6.008, 6.010
6.005, 6.007, 6.004
6.0156.0000.015
S066.003, 6.002, 6.003
6.005, 6.004, 6.003
6.002, 6.004, 6.003
6.0056.0020.003
S076.002, 6.000, 6.000
5.999, 6.001, 6.002
6.000, 6.001, 6.000
6.0025.9990.003
S086.000, 5.998, 6.001
6.000, 5.999, 6.000
5.998, 6.001, 6.000
6.0015.9980.003
S096.004, 5.995, 5.992
6.002, 6.000, 6.001
5.996, 5.998, 5.995
6.0045.9920.012
S105.991, 5.990, 5.998
5.995, 5.994, 5.996
5.992, 5.995, 5.993
5.9985.9900.008

Result: TTV ranged from 0.003 para 0.015 milímetro. Eight of the ten samples were controlled within 0.010 milímetro, demonstrating repeatable thickness uniformity under the selected cutting conditions.

4. Thickness Dimensional Tolerance

The average of the nine measurements for each sample was compared with the nominal 6.000 mm thickness.

AmostraAverage thickness (milímetro)Deviation (milímetro)
S015.992-0.008
S026.002+0.002
S035.996-0.004
S046.002+0.002
S056.008+0.008
S066.003+0.003
S076.0000.000
S086.0000.000
S096.0000.000
S105.994-0.006

Result: All sample averages were within +/-0.008 mm of the nominal thickness, meeting the +/-0.010 mm target.

5. Surface Roughness Results

Surface roughness was evaluated by stylus profilometry in accordance with ISO 4287. Three representative positions were measured on each sample: center, middle-left, and middle-right.

AmostraRa-1Ra-2Ra-3Ra médio (micrómetros)
S010.860.910.900.89
S020.820.850.860.84
S030.910.950.930.93
S040.870.920.910.90
S050.920.960.940.94
S060.730.760.750.75
S070.740.760.750.75
S080.800.830.820.82
S090.700.730.720.72
S100.790.820.810.81

Result: Average Ra values ranged from 0.72 para 0.94 micrómetros, with an overall mean of 0.82 micrómetros. The cut surfaces were suitable for subsequent precision grinding and polishing.

6. Edge-Chipping Results

All four edges of each sample were cleaned and inspected using an optically calibrated toolmaker’s microscope. The maximum defect observed along each edge was recorded.

AmostraPosição 1Posição 2Posição 3Posição 4Maximum (micrómetros)
S013.24.13.84.54.5
S023.54.64.24.84.8
S035.26.47.16.87.1
S043.64.54.84.24.8
S057.58.69.29.89.8
S063.04.24.04.54.5
S072.83.64.04.34.3
S083.54.04.64.84.8
S095.86.57.47.87.8
S105.06.26.87.57.5

Result: Maximum chipping remained below 10 micrometers for every sample. The results indicate uniform edge loading and stable wire guidance during the cut.

Finished 6 mm H-K9L optical glass sheet after endless diamond wire cutting
Figura 4. Finished H-K9L optical glass sheet after cutting.

7. Engineering Conclusion

This customer test demonstrates that the endless diamond wire process can produce thin H-K9L optical glass sheets with controlled thickness, low surface roughness, and limited edge chipping. Process stability depended on the coordinated use of a rigid gantry machine, controlled wire tension, a slow 5 avanço mm/min, cutting-oil lubrication, wire pre-running, and wear compensation.

The data provide a practical baseline for engineers evaluating precision separation of optical glass before grinding and polishing. Actual production parameters should still be validated for each glass composition, block geometry, fixture, and downstream quality requirement.

Discuss Your Optical Glass Cutting Requirement

Ensoll provides sample testing, machine selection, diamond wire specification, fixtures, and process development for optical glass and other hard and brittle materials. Review the ESO-GM machine, explore our máquina de corte de vidro óptico, or send your material dimensions and target tolerances for an application review.

Citation permission: If you find this article helpful, Ensoll authorizes you to quote or reference it, provided that you include a link to this page as the original source.

Perguntas Frequentes

What TTV can diamond wire cutting achieve on optical glass?

In this H-K9L test on 6 mm sheets, total thickness variation ranged from 0.003 para 0.015 mm across ten samples, with eight samples at or below 0.010 milímetro. Results depend on machine rigidity, wire condition, tension control and feed strategy.

Is H-K9L the same as Schott N-BK7?

They are comparable crown optical glasses used in many of the same optical applications. H-K9L has a Mohs hardness of about 6 e, like N-BK7, is widely used for lenses, prisms and windows — but they are not identical formulations, so processing parameters should be validated per material.

What surface roughness does diamond wire cutting leave on optical glass?

Neste teste, average Ra values ranged from 0.72 para 0.94 micrometers with an overall mean of 0.82 micrómetros, measured by stylus profilometry per ISO 4287. Surfaces at this level are suitable for subsequent precision grinding and polishing.

Why should a new diamond wire loop be pre-run before cutting?

A short no-load pre-run — 20 minutes in this test — removes loosely attached abrasive particles and stabilizes the wire before it touches the workpiece. Combined with wear compensation during the cut, this keeps thickness and surface quality consistent across samples.

Revisado pela equipa de engenharia da Ensoll.